i-on40
Page 7
control unit and 5 in Fig 8 for the keypad).
Fitting a jumper to the pins adds a
termination to the cable.
In a daisy chain configuration terminate
each end of the chain (see Fig 11 ).
In a star configuration:
If there are only two keypads then this
is the same as a daisy chain
configuration. If required terminate at
each keypad.
If there are more than two keypads
AND two cables are long while the
remaining keypad cables are short (less
than 10m) then it is possible to
terminate at the two keypads with long
cables.
If there are more than two keypads BUT
each keypad cable is more than 10m
then DO NOT terminate.
Keypad Addressing
Each keypad connected to an end station
must have a unique address. See Figure 8
on page 4 for the position of the addressing
jumpers.
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
*0#
MENU
A
B
1
4 ghi
7 pqrs
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
4
3
2
4
3
2
12
43
4
3
2
4
3
2
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
Figure 13 Keypad Addressing Jumpers
Backlight Control
You can control the appearance of the
keypad backlights and set/unset LEDs by
fitting links over the appropriate jumpers
on the keypad pcb (see Figure 8 on page 4
for the position of the jumpers).
The jumpers have the following functions:
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
ABCD-ON
The set/unset LEDs are disabled.
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
ABCD-ON
The set/unset LEDs shows the setting
status of the system. (Full set is left
hand led.)
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
ON
BRIGHT
BL
The key backlights are disabled. They
will glow briefly for five seconds when a
user presses a key.
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
ON
BRIGHT
BL
The key backlights glow all the time at
normal intensity.
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*0#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
ON
BRIGHT
BL
The keypad backlights glow all the time,
extra bright.
Tone Volume
To alter the volume of non-alarm tones
from the keypad adjust the keypad sounder
volume control (2 in Fig 8):
Louder
Note: This control changes
the volume of non-alarm
tones (for example
Exit/Entry tone). The volume
of alarm tones is fixed.
Softer
Step 3. Connect End
Station to Mains
WARNING: ENSURE THAT THE MAIN
SUPPLY IS DISCONNECTED AND ISOLATED
BEFORE MAKING ANY MAINS
CONNECTIONS. All mains electrical
connections must be carried out by a
qualified electrician and must comply with
the current local regulations (e.g. IEE).
Comentários a estes Manuais