Cooper Security i-on 16 Guia do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
i-on30EX
Page 28
Log capacity
Up to 350 events: 250
mandatory events, 100 non-
mandatory. Stored in
EEPROM memory, available
for at least 10 years without
power.
Internal Clock
±10 minutes over one year
(depending on the accuracy
of the mains supply
frequency).
User Codes
50 (plus installer code)
Remote controls
50 (one per user)
Panic Alarms
50 (one per user)
Proximity tags
50 (one per user)
Notes:
1. Wired keypads, wired zone expanders,
and radio zone expanders are all bus
devices. You can connect any
combination of these devices to the bus.
2. The system can be used as EITHER a
partitioned system OR a part setting
system. When used as a part setting
system there are four setting levels
available: Full Set and Part Sets B, C and
D.
Security
Security
Grade
Grade 2
Radio
detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
access codes
50 plus one installer
Access code
differs
10,000 differs with 4 digit
codes.
All digits may be any
number 0 to 9.
Code blocking
Blocked for 90s after 10
incorrect codes in series.
Proximity tag
differs
4,294,967,296 (2
32
)
Power Supply
This product complies with the requirements of
EN50131-6 Type A power supply at Grade 2 and
environmental class II.
Power supply type
A
Mains power supply
requirements
230VAC +10%/-15%,
200mA max, 50Hz.
Total power supply
capacity:
1.0A
(of which 200mA is
used for battery
recharge and 800mA
is available for
powering the
system).
12V Aux supply*:
550mA max
12V Bell supply*
550mA max
Comms power
supply*:
400mA max
12V Expander
Bus*:
400mA max
LS connectors
280mA in alarm.
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.
EN50131-6 ratings
The i-on30EX provides space for one 7Ah
battery.
For Security Grade 2 the required battery
standby time is 12 hours. This means that
all the devices powered by the backup
battery, including the control unit and at
least one keypad, should together draw no
more in total than an average of 580mA
over a 12 hour standby time.
The table below shows the current
consumption of the control unit and each
device that can be fitted to it.
CIE power
requirement:
100mA min.
120mA max
Keypad power
requirement:
30mA (backlight off)
45mA/65mA
(backlight norm/bright)
60mA in alarm
Wired Expander
requirement
20mA max quiescent.
300mA in alarm if
sounder connected.
Radio Expander
requirement
40mA max quiescent
320mA in alarm if
sounder connected.
Battery charging
requirement:
200mA (recharge
within 72 hrs)
Plug-on
Communicator
power requirement
(i-sd02 or i-dig02):
20mA quiescent
50mA max
Plug-by
Communicator pins
require:
5mA each when
active.
10 FSL zones
20mA
5 CCL zones
30mA
12V Bus output
voltage range :
10±0.5V to 13.8V
12V Aux output
voltage range:
10±0.5V to 13.8V
Vista de página 31
1 2 ... 27 28 29 30 31 32 33 34 35 36

Comentários a estes Manuais