Engineering Manual Engineer Menu 1-1
21
)
Except when in Walk Test mode (User option 1-1-2), all programmed zone types are active
and can be communicated to an ARC, even while an engineer is logged in. If the system is
connected to an ARC and work carried out the system could cause alarms to trigger, it is
recommended that you contact the ARC before work begins to avoid any unnecessary call-
outs.
You must program each zone using Engineer option 1-1 in order for the system to function
correctly. The number of available zones depends on the panel type and expansion devices you
are using (see page 2).
Use the following steps and the flowchart on the previous page to program a zone.
)
Advanced zone programming options are available in option 1-2.
Step 1 – Select Zone
The 4-digit number shown in the bottom-left corner of the display indicates the zone to be
programmed.
For all zones:
The first digit is the network number. This is the network number of the device that the
zone is connected to (0 for zones connected to the control panel PCB). The number of
available networks depends on the type of control unit; see pages 3 to 4 .
The next two digits specify the device address that the zone is connected to (00 for zones
connected to the control panel PCB). For devices such as keypads, the device address is
determined by a link or switch on the device PCB.
Note that the zones on keypads attached to MSNodes do not provide extra zones over and
above the eight zone provided by the MSNode.
The final digit specifies the zone number on the selected device.
Example: 2031 is (reading right to left): zone 1 of device address 03 connected to network 2.
Zones connected to the control panel are numbered 0001 to 0008.
Step 2 – Select Zone Type
The zone type defines how the panel will respond when the zone is triggered. The following
zone types are available:
)
By default, a zone is "triggered" by opening the zone contacts. If the zone's Inverted
attribute is set to YES (page 29), the zone triggers when the zone contacts close.
)
Copying zone details: Pressing B or
r
at step 2 copies all properties of the previously
programmed zone.
0 – Not Used
This zone never generates any alarm. It can, however, be used to operate an output
programmed to mimic the zone status; see page 58.
Vista de página 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 179 180

Comentários a estes Manuais

Sem comentários

Black & Decker 1 VPX VPX1201 manuales

Manuales del propietario y guías del usuario para Herramientas Black & Decker 1 VPX VPX1201.
Ofrecemos 1 manuales en pdf Black & Decker 1 VPX VPX1201 para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Herramientas Black & Decker

Modelos Tipo de documento
PS1440 Manual de usuario     Black & Decker PS1440 User Manual, 6 paginas
CHS6000 Manual de usuario     Black & Decker CHS6000 User Manual, 34 paginas
5145342-00 Manual de usuario     Black & Decker 5145342-00 User Manual, 6 paginas
90544571 Manual de usuario     Black & Decker 90544571 User Manual, 32 paginas
617623-00 Manual de usuario     Black & Decker 617623-00 User Manual, 6 paginas
BT3500 Manual de usuario     Black & Decker BT3500 User Manual, 5 paginas
D28494 Manual de usuario     Black & Decker D28494 User Manual, 57 paginas
90555829 Manual de usuario     Black & Decker 90555829 User Manual, 4 paginas
GCO1200 Manual de usuario     Black & Decker GCO1200 User Manual, 7 paginas
GCO9600 Manual de usuario     Black & Decker GCO9600 User Manual, 7 paginas
5147205-00 Manual de usuario     Black & Decker 5147205-00 User Manual, 6 paginas
BDG1200K Manual de usuario     Black & Decker BDG1200K User Manual, 6 paginas
Alligator LP1000 Manual de usuario     Black & Decker Alligator LP1000 User Manual, 2 paginas
DR260 Manual de usuario     Black & Decker DR260 User Manual, 36 paginas
DR200 Manual de usuario     Black & Decker DR200 User Manual, 6 paginas
1 VPX FLASHLIGHT Manual de usuario     Black & Decker 1 VPX FLASHLIGHT User Manual, 32 paginas
FSNS100 Manual de usuario     Black & Decker FSNS100 User Manual, 38 paginas
Fire Storm 496437-00 Manual de usuario     Black & Decker Fire Storm 496437-00 User Manual, 9 paginas
5102751-00 Manual de usuario     Black & Decker 5102751-00 User Manual, 6 paginas
FireStorm 90502477 Manual de usuario     Black & Decker FireStorm 90502477 User Manual, 7 paginas