Engineer Menu 1-4 Engineering Manual
42
Example 1: The gates in custom output 1 have the following default settings. If the
defaults are used, the custom output activates only when the system is full set AND there
is an alarm.
OR GATES AND GATES
1
Always Off
5
System Full Set
2
Always Off
6
System Full Set
3
Always Off
7
Alarm
4
Always Off
8
Alarm
Example 2: The gates in custom output 2 have the following default settings. If the
defaults are used, the custom output activates only when the system is full set AND there
is a confirmed alarm.
OR GATES AND GATES
1
Always Off
5
System Full Set
2
Always Off
6
System Full Set
3
Always Off
7
Confirmed
4
Always Off
8
Confirmed
Example 3: The following example shows how to program a custom output to enable it to
activate when a monitored power supply reports a "PSU - Power" event AND a selected
ward is set.
OR GATES AND GATES
1
Always Off
5
PSU - Power
2
Always Off
6
Set (Ward option 08)
3
Always Off
7
Set (Ward option 08)
4
Always Off
8
Set (Ward option 08)
Step 2 – Select Output Number
Select the output of the chosen type to set up. For example, if you have chosen to set up a
Panel output, select whether to set up output 1, 2, 3, 4, or 5.
NOTE:
The programmable output available on the keypad PCB is electronically linked to the
lower LED on the display. The LED is active when the output is active. There is a jumper
link “LED mimic” on the keypad pcb that you can remove if you wish the lower LED to
stay dark.
By default the keypad output is programmed as “Pending”. This means that it becomes
active if there are two (or more) alerts pending.
When connected to an MSNode, the keypad output follows one of the two outputs on the
MSNode. To program the function of the keypad output you must program the function of
one or other of the MSNode outputs.
To select which output the keypads will follow:
Give the keypad an even address (2 or 4) to follow output 2.