Appendix. Log Messages
Message
Meaning
AC Fail
Mains power supply
failed
AC Restore
Mains power supply
restored
Al Conf Dis K==
Alarm confirmation
disabled by lock switch
Al Confirm Z==
Confirmed alarm on
zone ==
Alarm Abort
User aborted alarm
AUX DC Fail
Auxiliary power failed
AUX DC Fail Rstr
Auxiliary power restored
ATE L.F. All
Line Fault input active
(problem with line or
communictor)
ATE L.F. Rstr
Line Fault input restored
(communicator or line
problem OK)
Bad Checksum
Control unit memory
corrupted
Batt Flt Rstr
Battery reconnected
Batt Load Fail
Battery failed load test
Batt Missing
Battery disconnected
Bell Tamper
Sounder tampered with
Bell Tamper Rst
Sounder tamper reset
Burg Z== Alarm
Intruder alarm on zone
==
Burg Z== Rstr
Intruder alarm on zone
== reset
Codes Defaulted
Access codes returned
to default values
Comms Fail
Communications failure
Common A/T
Common anti-tamper
zone has been activated
Common A/T
Common anti-tamper
zone restore
Config Change
System configuration
(site specific data) has
changed
Defaults Loaded
Default values loaded for
all commands
EEPROM Fail
Control unit memory
damaged
Fire Reset
Fire alarm reset
Message
Meaning
Fire Z== Alarm
Fire alarm on zone ==
Fire Z== Rstr
Fire alarm on zone ==
restore
Fr K== Alarm
Fire alarm started at
keypad ==
HUA Z== Alarm
Hold up alarm started in
zone ==
HUA Z== Rstr
Hold up alarm reset in
zone ==
K== Excess Keys
Incorrect access code
entered more than four
times at keypad ==
K== Missing
Keypad == disconnected
K== Restore
Keypad == reconnected
K== Tamper
Keypad == tampered
with
Lid Tamp Restore
Control unit lid tamper
reset
Lid Tamper
Control unit lid tampered
Low Bat Z==
Low battery detected on
transmitter ==
Low Bat Z== Rstr
Low battery reset on
transmitter ==
Low Batt Rstr
Low battery detected on
control unit
Low Batt Rstr Z==
Low battery reset on
control unit
Set Fail Z==
System failed to set
because of fault in zone
==
Soak Fail Z==
Soak test failed in zone
==
System Rearmed
System rearmed after an
alarm
System Startup
Power applied to system
System Tamp Rst
System tamper reset
System Tamper
System tamper
Tamper K== Rstr
Keypad == tamper reset
Tamper Z==
Zone == tampered with
Tamper Z==
Tamper in zone ==
during the day
Tamper Z== Rstr
Zone == tamper reset