4. Programming
Page 114 496964
185: Keyswitch Auto Reset
This Command instructs the control unit to reset a tripped keyswitch zone
automatically if the user uses the keyswitch to set the system on leaving.
Option
0 Off. User must reset tripped zones manually.
1 On. System resets a tripped zone of type KM or KF automatically
when the user sets the system with the keyswitch.
186: Set Home Beep Calls
This Command sets the number of times that the control unit will call if
Reporting Type is set to Home "beep" (Command 103, option 6). The
repeated message acts as a confirmation.
Enter two digits, from 01 to 15 (default 02). The default is usually sufficient,
providing one call to alert the user and a second call to confirm the alert. For
the 9851 only, the user can acknowledge the call by pressing "5" on the
telephone handset; this terminates the series of home "beep" calls.
Note: This Command sets the number of successful calls the system makes. It
does not include retries after failed communication attempts, which are
built into the various protocols used to control communications generally.
187 to 190: Not used
These commands are not used.