1. Introduction
Page 6 496964
Keypad
Figure 2. 9930 Keypad
The 9930 keypad has a 16-character Liquid Crystal Display (LCD) that shows
"first to alarm" information, level status and programming commands. In
addition, there are three LEDs that have the following functions:
a Glows steadily when mains power is present. Flashes when the
system is working from battery backup.
f Glows steadily when the system is unset if a telephone line fault is
present.
s Glows steadily when the system is unset if:
a) A fault or tamper circuit is active.
b) The system needs an engineer or remote reset.
c) A telephone line fault is present.
The 9930 keypad provides the following keys:
9 Used to start a Walk Test of the detectors.
8 Used to start a test of the Bell and Strobe outputs.
7 Used to enable or disable the Chime facility.
6 Used to set the internal clock calendar, which provides a time stamp
on printed log entries.
5 Used to display the log (250 events).
4 Used to change the User access codes.
0 Used to call an ARC to request a download.
Y Used to enter programming and setting/unsetting commands.
X Used to set the system with individual zones (including 24-hour
zones) temporarily omitted.
ABCD Used to set levels or partitions.