
4. Programming
Page 88 496964
77: Level/Partition D Alarm Response
This Command sets the Alarm Response for Level or Partition D.
In a single system, the options are:
Option
0 Keypad sounders only.
1 Internal sounders and keypad sounders.
2 Local alarm (internal and external sounder only).
3 Full alarm (communication and internal/external sounders).
In a partitioned system, the options are:
Option
0 Keypad sounders only.
1 Local alarm (internal and external sounder only).
2 Full alarm (communication and internal/external sounders).
78: Level D Entry Time
This Command has been replaced by Command 204.
79: Level/Partition D Exit Time
This Command sets the Exit Time for Level or Partition B.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Note: In a single system, you cannot change the operation of the Final Exit
and Entry Route zones assigned to Level D. For this reason, Cooper
Security recommends that you use this level for simple applications only.
Comentários a estes Manuais