Installer Mode Programming i-on40
Page 36
Type: Active when: Assign to
Partitions?
Panel A/C Fail
(12)
Either Mains power is
absent for between 52 and
59 minutes, OR a zone of
type “External PSU A/C
Fail” has been triggered.
The control unit deactivates
the output if a user keys in
a valid access code after
mains power has been
restored.
Note: If the External PSU
A/C Fail zone is activated
while the control unit is still
receiving mains power then
the control unit will
activate this output within
a few seconds.
If the control unit is not
receiving mains power then
it assumes that there is a
general power cut and
waits for 52 to 59 minutes.
No