Appendix I Installer Menu Defaults
Important: Where noted below the defaults listed enable
the control unit to comply with EN50131 requirements. If
you change these setting then the installation may no
longer comply. If the control unit does not comply with
EN50131 you must remove any labelling that indicates
compliance.
DETECTORS/DEVICES
ZONES 1 - 40
Name: “Zone nn”
Type: Not used
Partitions: Partition 1
Attributes:
Chime: No
Soak Test: No
Double Knock: No
Part Set B: No
Part Set C: Yes
Part Set D: Yes
Part Set: No
Omittable: No
Force Set Omit: No
WIRED/RADIO KEYPADS
Name: “KP0n” or “RKP0n”
Partitions: Partition 1 - 4
Key A:
Name: “Key A”
Action: Partition 1 Full Set
OR Full Set
Key B:
Name: “Key B”
Action: Partition 2 Full Set
OR Part Set B
Key C:
Name: “Key C”
Action: Partition 3 Full Set
OR Part Set C
Key D:
Name: “Key D”
Action: Partition 4 Full Set
OR Part Set D
EXTERNAL SIREN 1 - 4:
Partition 01
INFO MODULES
Updates: Disabled
Rdy to set LEDs: Disabled
OUTPUTS
All outputs allocated to all partitions.
RADIO OUTPUTS 1 - 8
Name Type Polarity
Output 1-8 Not Used Normal
WIRED OUTPUT 1 - 4
Name Type Polarity
Output 1 Siren Normal
Output 2 Strobe Normal
Output 3 Siren Normal
Output 4 Strobe Normal
PLUG BY OUTPUT 1 - 12
Name Type Polarity
Output 1 Fire Normal
Output 2 Panic Alarm Normal
Output 3 Burglar Alarm Normal
Output 4 Open / Close Inverted
Output 5 Omit (System) Normal
Output 6 Alarm Abort Normal
Output 7 Confirmed Normal
Output 8 Technical Normal
Output 9 Panel AC Fail Normal
Output 10 Panel Batt FaultNormal
Output 11 General Fault Normal
Output 12 Tamper Normal
PART SETTING OPTIONS
FULL SET
Name: “Full Set”
Exit Mode: Timed Set
PART SET B, C AND D
Exit Mode: Instant Set
Alarm Response: Internal+Siren
Part Set Final Exit: Final exit
Part Set Entry Route: Entry Route
PART SET B NAME:
“Part Set B”
PART SET C NAME:
“Part Set C”
PART SET D NAME:
“Part Set D”
EXIT TIME:
40s
(See Note 2)
ENTRY TIME:
45s
Note: The maximum time permitted by
EN50131-1 Clause 8.3 is 45 seconds.
STROBE ON SET:
Disabled
(See Note 2)
STROBE ON UNSET:
Disabled
PARTITIONS 01 - 02
Name: “Partition 1”
Exit Mode: Timed Set
Exit Time: 45
Entry Time: 45
Note: The maximum time permitted by
EN50131-1 Clause 8.3 is 45 seconds.
Alarm Response: Siren + Comms
Part Set Exit Mode: Instant Set