i-on40 Installer Mode Programming
Page 51
System Tampers
Yes The user can reset the system after an alarm
caused by a system tamper, for example the
control unit lid opening, or a keypad being
opened.
No The installer must reset the system after a system
tamper alarm.
Note: This setting is required for INCERT approval.
DD243 (UK Only)
Note: This menu is visible only when System Options –
Restore Defaults – Country defaults is set to “UK”.
In order to program your requirements for DD243 select
System Options - DD243. The options available are:
Confirmation
When set to ‘On’ this option enables the features
designed to ensure the system complies with
DD243:2004.
Note: When using Confirmation, and the system is
programmed for Installer Reset after an alarm, the
user cannot set the system after an alarm until the
installer has carried out a reset.
Confirmation Time
This option determines the length of the confirmation
time.
After Entry
Never: The control unit turns alarm confirmation off
if the user enters by the entry door (used for
DD243:2004 clauses 6.4.2 and 6.4.4).
1 zone: The control unit starts a confirmed alarm if
the intruder activates one or more zones, not on the
entry route, after entering the premises through the
final exit zone.
2 zones: The control unit starts a confirmed alarm if
an intruder activates two (or more) zones, not on the
entry route, after entering the premises through the
final exit zone (used for DD243:2004 clauses 6.4.5).