i-on40 Installer Mode Programming
Page 41
Type: Active when: Assign to
Partitions?
Smoke Sensor
Reset (28)
This output is active (0V)
all the time except when a
user acknowledges a fire
alarm: after which the
control unit deactivates the
output for three seconds.
This output type is
designed to be connected
to low-voltage smoke
detector reset terminals.
Yes
24 Hour
Alarm (29)
The control unit starts a 24
hour alarm.
Yes
Setting
Complete (30)
The control unit finishes
setting. Active for 10
seconds.
Yes
Unset
Complete (31)
Someone unsets the
system or disarms it after
an alarm. The output is
active for 10 seconds.
Yes
Full Set Ready
(32)
None of the detectors are
reporting “alarm” signals.
Yes
Full Set (33) The system is full set. If
the system is partitioned,
then the output is active
only when all assigned
partitions are Full Set.
Yes
Part Set (34) The system is part set. Yes
Part Set B
(35)
Setting Part Set B.
Deactivated on unsetting
Part Set B. (Available only
in a Part Setting system)
No
Part Set C
(36)
Setting Part Set C.
Deactivated on unsetting
Part Set C. (Available only
in a Part Setting system)
No