i-on160 Installer Menu Options
Page 97
IP Address This is the IP address the control unit uses when linked by
Ethernet to a PC.
Subnet Mask This is the subnet mask currently in use by the control unit
itself.
Gateway Address
T
his is the
g
ateway address bein
g
used by the control unit.
MAC Address This is the unique MAC address of the control unit pcb.
Each control unit pcb will have an individual MAC address.
IP Link Status This option shows the current status of the Ethernet link
between a PC and the control unit. The display shows “Fail”
when there is no link, and “OK” when the Ethernet link is
established. Note that “OK” only shows that the link is
established, it does not show that the PC is logged into the
control unit.
Module: Shows the identity of the communications module currently fitted.
Zone Mapping
This option allows you to check which zones are currently allocated to detector
connection points, or which detector connection points have zone numbers
allocated. There are two options:
Zone Number
The display shows a list of zone numbers (with names), with detector
connection points for each zone.
Zone address
The display shows a list of detector connection points, with zone numbers
and names, where allocated.
Non-Programmable Functions
Alarm Abort
The i-on160EX contains a fixed Alarm Abort Delay period of 90 seconds. The
control unit starts the Alarm Abort Delay timer whenever it starts an alarm. If
a user silences the alarm within the Abort Delay period, the alarm will not
require an engineer or remote reset.
If an alarm occurs and a user unsets the system within the Alarm Abort Delay
period then the control unit activates any output of type Alarm Abort (page 46)
and starts any Alarm Abort Fast Format communications programmed.
Remote Reset (RedCare Reset)
If the system is configured for installer reset only (you have programmed
option System Options – User Reset – Zone alarms as “No” or System Options - DD243
- Confirmation is “On”) then the control unit enables the Remote Reset input pin
on the its plug by connector. After an alarm, the user can silence the sounders
but must contact an Alarm Receiving Centre (ARC) to reset the system.
The ARC verifies the user’s identity and (provided that the control unit is fitted
with a suitable plug-by communicator) can send a +12v signal to the remote