i-on160 Step by Step Programming Procedures
Page 113
6. Press Y.
The display shows a message asking you to
confirm your choice. (Press X if you want to
change your mind.)
Delete ALL detectors
and zone data?
6. Press Y.
The display shows a second message asking you
to confirm your choice. (Press X if you want to
change your mind.)
Note: The deletion will take place immediately, and
not when you leave Installer Mode.
Are you sure?
7. Press Y to confirm your choice.
After a short message confirming that the
control unit has deleted all the radio detectors
the display returns to the Delete All menu.
ADD/DEL DETECTORS
Delete All >
To reinstate the detectors you must teach the control unit each detector's
identity again (see page 110).
Changing Zone Names, Type, Attributes and Partitions
1. Enter Installer Menu.
INSTALLER MENU
Detectors/Devices >
2. Press Y.
DETECTORS/DEVICES
Detectors
3. Press Y .
DETECTORS
Add/Del Detectors
4. Press n until the display shows:
DETECTORS
Program zones
5. Press Y .
The bottom line of the display shows the first
zone.
Z001 P0<00<00 NU
Zone 000 >
6. Press u or n to show the other zones.
Z002 P0<00<02 NU
Zone 002 >
(Hint: You can key in the zone number you wish
to edit, for example:“012” for zone 12.)
The top line of the display shows the zone
number, the detector connection point and the
current zone type (NU = Not Used).