Installer Menu Options i-on160
Page 72
No Alert Tones
The keypad gives no alert tone. (The red LEDs around the navigation key
glow to show that there is an alert.)
Mains Fail Delay
This option controls the length of time that the control unit waits until starting
an alert if the mains supply fails. The values available are 0 to 10 minutes.
Note that when the value is set to 0 minutes, mains interruptions of less than
9 seconds will not start an alert.
Battery 2
This option can enable or disable alert reporting on the second backup battery.
The options are:
Enabled
The control unit will start an alert if battery 2 is missing or low voltage.
Disabled
The control unit will ignore the presence or absence of battery 2.
Communications
Note: If you have connected a plug-by communicator then use the Outputs -
Plug-by Outputs menu to program the communicator.
The Communications option in the Installer Menu contains all the options
needed to program how the control unit will communicate alarms. Within the
Communications option, the main menu items deal with the following areas:
ARC Reporting
Deals with reporting to a central station using either SIA, CID or Fast
Format.
Speech Dialler
Deals with recording speech messages, selecting the alarm types that will
trigger them, and selecting destinations for the messages. This sub-menu
is visible only when the i-sd02 or i-gsm-2 modules are fitted.
SMS
Deals with setting up text messages, selecting the alarm types that will
trigger them an selecting their destinations. This sub-menu is visible only
when the i-sd02 or i-gsm-2 modules are fitted.
Line Fail Reporting
Allows you to select how the control unit reports a communications failure.
IP Network (Own)
The Web Server sub-menu deals with setting the control unit’s own IP
address and access to the built in web-pages.
The other sub-menus within IP Network (Own) menu allow you to set up
the IP address and other parameters for any attached Ethernet or GPRS
modules. These sub-menus will not appear if the modules are not fitted.
Downloading
Deals with setting up phone numbers, account numbers for the
downloader, and controlling the type of connection you wish to allow.
Vista de página 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 179 180

Comentários a estes Manuais

Sem comentários