i-on160 Installer Menu Options
Page 73
Note: Apart from Downloading and IP Network (Own), the above menu items
appear only if the appropriate module is fitted.
The control unit is designed to alert the user if it fails to complete a
programmed communication. If alarm reporting fails then the keypad displays
an alert by lighting the red LEDs around the navigation keys. Although the user
may acknowledge the alert, the control unit will not remove the alert until
communication is completed successfully.
If you wish to remove a communications module from a system, ensure that
you first disable communications in the appropriate menus:
To remove a: Disable:
i-sd02, i-gsm02 ARC Reporting, Speech Dialler, SMS
GPRS, Ethernet ARC Reporting, IP Network
Otherwise the control unit will continually report a communications failure.
ARC Reporting
To program how the control unit will communicate with an ARC select
Communications - ARC Reporting.
Call Mode
To choose the call mode for communicating with an ARC select: Communications
– ARC Reporting – Call Mode. The call modes available are:
Disabled.
The control unit disables all ARC communications.
Note: If you have fitted an 8750 module to the control unit then the module
will continue to send Poll calls to the ARC even if you set call mode to
disabled. (The ARC will not receive alarm or test calls.) If you also
disconnect the Ethernet cable from the 8750 module the control unit will
not raise a Line Fail or Poll Fail alert, because you have set the call mode
to disabled.
Single.
The control unit reports to the first telephone number in the Phone Book,
using a single account number (see "Account Numbers" on page 74).
Operation: The control unit dials the number and attempts to connect with
the ARC. If the call fails, the control unit ends the call and then re-
attempts to connect up to a maximum of 15 times.
Alternate.
The control unit reports to one of the two telephone numbers in the Phone
Book.
Operation: The control unit dials the first telephone number and attempts
to connect to the ARC. If it fails, it will then close down and dial the
second telephone number and attempt to connect to the ARC. If received
and acknowledged on this attempt, the alarm transmission is complete. If
the control unit fails to connect to the second telephone number, it will
close down again and re-attempt to connect to the first telephone
number. The control unit will continue to shuttle between the two
numbers up to 15 times.