Installer Menu Options i-on160
Page 70
Entry Alarm Delay
Use this option to determine what the system will do if a user strays from an
Entry Route zone during entry. (This option is available to provide compliance
with EN 50131-1.)
Select “No” to make the system give an alarm immediately if the user strays
from an entry route zone during entry. Note: This is not compliant with
EN50131.
If you select “Yes” and the user strays from an entry route zone during entry
then the system waits 30 seconds before raising a full alarm. The system also
gives an internal alarm during the 30 second wait.
If the user enters an access code or presents a tag before the end of the 30
seconds internal alarm then the user can reset the system.
Supervision
If a wirefree detector loses contact for more than 20 minutes then the control
unit logs the event as “RF Warning”. In addition, the control unit inhibits
setting. If a user overrides the inhibition then the control unit logs the event as
an RF warning override.
If a wirefree detector loses contact for more than two hours then the control
unit raises an alarm. The options available for this alarm are:
Option: With system SET, the
control unit:
With system UNSET the
control unit:
Disabled Does nothin
g
. Does nothin
g
.
Fault Logs the event (but does NOT
display any alert or fault
tone).
Displays an Alert and sounds a
fault tone and logs the event.
Jamming
The control unit can detect interfering (or "jamming") radio signals. To enable
jamming detection select System Options - Jamming.
If the control unit detects jamming once you have enabled this option then the
display shows an Alert message for the user.
Force Set
You may wish to allow a user with a remote control to set the alarm system
when one or more of the detectors are not working or are open (active).
Note: If you enable “Force Set” then the system does not comply with
EN50131.
There are three options available:
Off
The remote control user cannot force set the system, even if you have
applied the force set zone attribute to any zones.
Confirm
The remote control user can force set the system. They must operate as
follows: 1) the user presses the appropriate button to set the system, 2)
the control unit does not start setting, 3) the user presses the same
Vista de página 75