Installer Menu Options i-on160
Page 34
Normal Alarm (03).
When triggered, a zone programmed as ‘Normal Alarm’ will start an alarm
provided the system is set.
When the control unit first learns a radio detector the zone type defaults
to Normal Alarm.
24 Hour Alarm (04).
Activating this zone causes an internal alarm (keypads and speakers)
whether the system is set or unset.
Final Exit (05).
Zones of this type must be the last detector to be activated on exit, or the
first to be activated on entry. You can use zones of this type to finally set
the system or partition, or to start the entry procedure. See page 54 to
set the exit mode type.
Note: If you give a Final Exit zone any of the Part Set attributes then you can
program that zone to behave like a Normal Alarm zone if the user part
sets the system. See page 55 .
Entry Route (06).
Use this zone type for detectors sited between the Final Exit door/detector
and the keypad. If an ‘Entry Route’ zone is triggered when the system is
set, an alarm will occur. If the entry/exit timer is running when an Entry
Route zone is triggered then no alarm occurs until the entry/exit timer
expires.
Note: If you give an Entry Route zone one of the Part Set attributes then you
can program that zone to behave like a Final Exit zone if the user part
sets the system. See page 55 .
Technical Alarm (07).
Use this zone type when you want to monitor equipment, for example a
freezer, without raising a full alarm. If a technical alarm zone is activated
then the control unit logs the event and (if the control unit is correctly
programmed, see page 72) starts communication.
If the technical alarm occurs while the system is set, then system makes
no audible alarm. When a user unsets the system the keypad shows an
alert.
If a technical alarm zone is activated while the system is unset then the
system starts an alert immediately and gives a brief tone from the keypad
every few seconds. When a user enters a valid access code the keypad
stops the tone and displays the zone causing the alarm.
When the user acknowledges the alert by pressing Y the control unit
resets the technical alarm ready for the next event.
Key Switch Momentary (08).
Use this zone type to connect a momentary keyswitch to a single zone.
In a Part Setting system the keyswitch can Full Set or unset.
In a Partitioned system you can allocate the keyswitch to one or more
partitions.
Each time a user operates the keyswitch the control unit changes the
current set state.
Key Switch Latched (09).
Use this zone type to connect a fixed position keyswitch to a single zone.