Cooper Security i-on160EX Guia de Instalação Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 180
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
Installer Menu Options i-on160
Page 52
In the Installer Menu, while programming a user output type, the control unit
gives you the following options:
Polarity
Polarity can be either Normal or Inverted. This option works the same way
as described for Wired Outputs – see page 45.
Latched
Latched can be either Yes or No.
No: The output initially changes state when a user operates the output,
but then changes state again after a set time. The time is fixed by the “On
Time” option, below.
Yes: The output changes state every time a user operates the output. In
addition, three new menu options appear that allow you to set an On time
and Off time for any day of the week, see below.
On Time
If you select Latched = No, then use this option to key in the number of
seconds the output should remain active. You can select any period
between 1 and 999 seconds. Note that if you select an active time of zero
seconds then the output will not operate.
On Time/Off Time/Days
If you select Latched = Yes, then use these three options to make a user
defined output come on and go off in a regular pattern.
On Time: Key in the time on the 24 hour clock when you want the output
to activate.
Off Time: Key in the time on the 24 hour clock when you want the output
to deactivate.
Days: Select one or more days of the week when you want the output to
operate.
The control unit will operate the output at the times selected. However, if
a user activates the output while it is Off, then the output stays on until
the control unit reaches the next Off time. If a user de-activates the
output while it is On, then the output stays off until the control unit
reaches the next On time.
If you do not key any values into On Time/Off Time/Days, then the output
acts as a simple On/Off switch under control of the user.
“Setting Options” and “Partitions” Menus
Part Setting or Partitioned System?
When you first power-up a new i-on160EX (see i-on160EX Installation Guide ),
or if you restore an i-on160EX control unit to factory defaults (see page 67 ),
you must choose between having a Part Setting system or a Partitioned
system.
If you select a Part Setting system then the Installer Menu contains a “Setting
Options” sub menu. If you select a partitioned system then the installer menu
contains “Partitions” sub-menu instead.
Both of these menus contains the same options, but organised in slightly
different ways:
Vista de página 57